690v static var generator statcom is a new type of electronic device for dynamic compensate reactive power . It can conduct real-time compensation to dynamic reactive power, and is used to overcome disadvantages of reactive compensation methods of traditional filters,thus realizing systematic reactive power compensation function. In addition, it is widely applied into power,metallurgy. petroleum, port, chemical and industrial and mining enterprises.
1. Modular design, any module failure will not affect the normal operation of other modules, greatly improving the reliability of the whole equipment; can achieve smooth expansion of multiple direct parallel operation.The master-slave control mode is used when multiple units are expanded; when multiple modules are connected in parallel, all modules can share a set of current transformers.
2. The odd-order harmonic currents of 2 to 50 times or less can be filtered out at the same time, and the harmonics of the 13 types of filtering can be set as needed.When the load current distortion rate is >20%, not less than 85%; when the load current distortion rate is <20%, not less than 75%; reactive power compensation can make the power factor reach 1; the three-phase current unbalance can be corrected to complete balance;
3. Use the fifth generation IGBT of imported international well-known brand, it can automatically adjust the output according to the harmonic current of the load, and dynamically filter;
4. Use the American Xilinx military-grade FPGA control chip, which has fast running speed and high reliability;
5. With a layered design, dust and rain will not adhere to the circuit board, adapting to the use under harsh conditions;
6. Filtering, compensating reactive power, compensating for three-phase unbalance can be single-selected or multi-selected, and can set the priority of functions;
7. Use the iterative DFT detection algorithm of sliding window , the calculation speed is fast, the transient response time is less than 0.1ms, and the full response time of device compensation is less than 20ms;
8. The output filtering uses the LCL structure to connect to the grid, and its own high-frequency carrier does not feed back to the grid, and there is no interference to other devices in the power distribution system;
9. Complete protection functions, including over-voltage, over-current, over-heat, short-circuit and other complete protection functions, as well as system self-diagnosis function;
10. It has a soft start control loop to avoid excessive inrush current at the moment of starting, and limits the current between the rated ranges;
11. Use the reliable current limiting control link. When the current to be compensated in the system is greater than the rated capacity of the device, the device can automatically limit the output to 100% capacity, maintain normal operation, and no faults such as overload burning;
12. The main circuit uses a three-level topology, and the output waveform has high quality and low switching loss;
13. The wall mounted module comes with a 4.3 touch screen for parameter setting, parameter viewing, status viewing, event viewing and more.It can also be centrally monitored by high-definition 7-inch touch screen, which is easy to operate. The screen displays the system and device operating parameters in real time, and has a fault alarm function.
14. Save space for users, the maximum power of 600mm wide cabinet is 300A/200kvar, and the power of 800mm wide cabinet can reach 750A/500kvar.
After the circuit breaker is closed, in order to prevent the instantaneous impact of the grid on the DC bus capacitors during power-on, the APF/SVG firstly charges the DC bus capacitor through the soft-start resistor.When the bus voltage Udc reaches a predetermined value, the main contactor is closed.As a energy storage device, the DC capacitor supplies energy to the external output of the compensation current through the IGBT inverter and the internal reactor.The APF/SVG sends the current signal through the external CT to the signal conditioning circuit and then to the controller.The controller decomposes the sampling current, extracts each harmonic current, reactive current, and three-phase unbalanced current, and compares the collected current component to be compensated with the compensation current that has been sent by APF/SVG to obtain a difference. The real-time compensation signal is output to the driving circuit, and the IGBT converter is triggered to inject the compensation current into the power grid to realize closed-loop control and complete the compensation function.
Network voltage(V) | 690 | |||
Network voltage range | -20%--+20% |
|||
Network frequency(Hz) |
50/60(-10%--+10%) |
|||
Harmonic filtering capability | It is better than the standard JB/T11067-2011 low voltage Active Power Filter. | |||
CT mounting method |
Closed or open loop(Open loop is recommended in parallel operation) |
|||
CT mounting position |
Grid side/load side |
|||
Response time |
<20ms |
|||
Connection method |
3-wire/4-wire |
|||
Overload capacity |
110%Continuous operation, 120%-1min |
|||
Circuit topology |
Three-level topology |
|||
Switching frequency(khz) |
20kHz |
|||
Protective function |
Parallel between modules |
|||
Redundancy | Over 20 kinds of protections such as over-voltage, under-voltage, overheating, over-current, short circuit, etc. | |||
Display |
No screen/4.3/7 inch screen(optional) |
|||
Single module capacity(kvar) | 50、100 | |||
Communication port |
RS485 |
|||
Communication method |
RS485,Modbus protocol |
|||
PC software | Yes, all parameters can be set by the host computer | |||
Error alarm | Yes, up to 500 alarm messages can be recorded | |||
Monitoring | Support independent monitoring of each module / centralized monitoring of the whole machine | |||
Noise level |
<60dB |
|||
Mounting type | Wall-mounted, rack-mounted, cabinet | |||
Altitude |
Derating usage>1500m |
|||
Temperature |
Operating temperature: -45℃--55℃, derating usage above 55℃ |
|||
Storage temperature: -45℃--70℃ |
||||
Humidity |
5%--95%RH, non-condensing |
|||
Protection class |
IP42 |
|||
Certification |
CE, CQC |
The 690v static var generator svg adopts the hardware structure of DSP, and the components are of high quality. Thermal simulation technology is used for thermal design of the system, and multi-layer PCB circuit board design ensures reliable isolation of high and low pressure, which provides guarantee for system safety.
690v static var generator can be widely used in power system, electroplating, water treatment equipment, petrochemical enterprises, large shopping malls and office buildings, precision electronics enterprises, airport/port power supply system, medical institutions and so on.
690v static var generator mostly used as below:
1) Data center and UPS system;
2) New energy power generation, e.g. PV and wind power;
3) Precision equipment manufacturing, e.g. single crystal silicon, semiconductoe;
4) Industrial production machine;
5) Electrical welding system;
6) Plastic industrial machinery, e.g. extrusion machines, injection molding machines, molding machines;
7) Office building and shopping mall;
1. ODM/OEM service is offered.
2. Quick order confirmation.
3. Fast delivery time.
4. Convenient payment term.
At present, the company is vigorously expanding overseas markets and global layout. We are committed to becoming one of the top ten export enterprises in China’s electrical automatic product, serving the world with high-quality products and achieving a win-win situation with more customers.