220v Mini SVG can balance load between phases and unloaded neutral wire for input voltage connection systems such as 3P3W and 3P4W. Therefore, i t will be a perfect solution with applications having reactive power requirements along with unbalanced loads, which is the case with the electricity distribution in rural areas,some industrial applications and much more.
1. The rate factor value can reach >0.99, and will not cause over-compensation and under-compensation;
2. Ultra-fast dynamic compensation, full response time less than 10ms;
3. Active compensation device to avoid resonance;
4. Can be combined with capacitors to form a hybrid compensation scheme;
5. Active power compensation equipment;
Network voltage(V) | 220 | |||
Network voltage range | -20%--+20% |
|||
Network frequency(Hz) |
50/60(-10%--+10%) |
|||
Individual module capacity(kvar) |
5、10、15、20 |
|||
Overall efficiency |
>97% |
|||
Harmonic filtering capability | It is better than the standard JB/T11067-2011 low voltage Active Power Filter. | |||
CT mounting method |
Closed or open loop(Open loop is recommended in parallel operation) |
|||
Response time |
<7.8ms |
|||
Connection method |
3-wire/4-wire |
|||
Overload capacity |
110%Continuous operation, 120%-1min |
|||
Circuit topology |
Three-level topology |
|||
Switching frequency(khz) |
20kHz |
|||
Protective function |
Parallel between modules |
|||
Redundancy | Over 20 kinds of protections such as over-voltage, under-voltage, overheating, over-current, short circuit, etc. | |||
Display |
4.3 inch screen |
|||
Communication port |
RS485 |
|||
Communication method |
RS485,Modbus protocol |
|||
PC software | Yes, all parameters can be set by the host computer | |||
Error alarm | Yes, up to 500 alarm messages can be recorded | |||
Monitoring | Support independent monitoring of each module / centralized monitoring of the whole machine | |||
Noise level |
<60dB |
|||
Mounting type | Wall-mounted, rack-mounted, cabinet | |||
Altitude |
Derating usage>1500m |
|||
Temperature |
Operating temperature: -45℃--55℃, derating usage above 55℃ |
|||
Storage temperature: -45℃--70℃ |
||||
Humidity |
5%--95%RH, non-condensing |
|||
Protection class |
IP42 |
Statcom svg can be widely used in power system, electroplating, water treatment equipment, petrochemical enterprises, large shopping malls and office buildings, precision electronics enterprises, airport/port power supply system, medical institutions and so on. According to the different application objects, the application of static var generator will play a role in ensuring the reliability of power supply, reducing interference, improving product quality, extending equipment life, reducing equipment damage and so on.
Statcom static var generator mostly used as below: Fast inductive and capacitive reactive power compensation, and can balance three-phase loads and eliminate harmonics
• Data Center and UPS system
• New energy power generation, e.g. PV and wind power
• Precision equipment manufacturing, e.g. single crystal silicon, semiconductor
• Industrial production machine
• Electrical welding system
• Plastic industrial machinery, e.g. extrusion machines, injection molding machines, etc.
• Office building and shopping mall
1. ODM/OEM service is offered.
2. Quick order confirmation.
3. Fast delivery time.
4. Convenient payment term.
At present, the company is vigorously expanding overseas markets and global layout. We are committed to becoming one of the top ten export enterprises in China’s electrical automatic product, serving the world with high-quality products and achieving a win-win situation with more customers.